{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T13:15:11.774","vulnerabilities":[{"cve":{"id":"CVE-2017-7914","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2017-06-14T21:29:00.270","lastModified":"2025-04-20T01:37:25.860","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"A Missing Authorization issue was discovered in Rockwell Automation PanelView Plus 6 700-1500 6.00.04, 6.00.05, 6.00.42, 6.00-20140306, 6.10.20121012, 6.10-20140122, 7.00-20121012, 7.00-20130108, 7.00-20130325, 7.00-20130619, 7.00-20140128, 7.00-20140310, 7.00-20140429, 7.00-20140621, 7.00-20140729, 7.00-20141022, 8.00-20140730, and 8.00-20141023. There is no authorization check when connecting to the device, allowing an attacker remote access."},{"lang":"es","value":"Se ha descubierto un problema de falta de autorización en Rockwell Automation PanelView Plus 6 700-1500 6.00.04, 6.00.05, 6.00.42, 6.00-20140306, 6.10.20121012, 6.10-20140122, 7.00-20121012, 7.00-20130108, 7.00-20130325, 7.00-20130619, 7.00-20140128, 7.00-20140310, 7.00-20140429, 7.00-20140621, 7.00-20140729, 7.00-20141022, 8.00-20140730 y 8.00-20141023. No hay comprobación de autorización al conectarse al dispositivo, lo que permite que un atacante logre el acceso remoto."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H","baseScore":8.6,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":4.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-882"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-862"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:6.00-20140306:*:*:*:*:*:*:*","matchCriteriaId":"A7EBA0A2-F6F2-4DF0-8FAC-37E5C6768734"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:6.00.04:*:*:*:*:*:*:*","matchCriteriaId":"7498C8EB-B040-4B5E-BB67-630986C417E7"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:6.00.05:*:*:*:*:*:*:*","matchCriteriaId":"5DC3FD03-CA9F-427D-B8AB-2280A60738B6"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:6.00.42:*:*:*:*:*:*:*","matchCriteriaId":"7522CC96-D5E9-41AF-95AB-876303767B1B"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:6.10-20140122:*:*:*:*:*:*:*","matchCriteriaId":"8B07AC6A-EFDA-4CC5-937C-6CAD73B3A1C2"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:6.10.20121012:*:*:*:*:*:*:*","matchCriteriaId":"00391FDB-1094-4FB3-9938-9DEDB1045AD9"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:7.00-20121012:*:*:*:*:*:*:*","matchCriteriaId":"374DABE1-5D77-4EE3-853A-9FF5AD820861"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:7.00-20130108:*:*:*:*:*:*:*","matchCriteriaId":"031AD257-1BE1-4061-BC6D-1AA0741C99EC"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:7.00-20130325:*:*:*:*:*:*:*","matchCriteriaId":"3F9743D5-67E5-4DA5-BFDB-E42CD73A8306"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:7.00-20130619:*:*:*:*:*:*:*","matchCriteriaId":"3C4A0042-86AF-4BB9-9114-F19777F6312A"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:7.00-20140128:*:*:*:*:*:*:*","matchCriteriaId":"78DDD0D2-E7F6-43A9-99A6-6D12B153BB1D"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:7.00-20140310:*:*:*:*:*:*:*","matchCriteriaId":"48CAEE93-3120-4F22-8BE0-46195D489015"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:7.00-20140429:*:*:*:*:*:*:*","matchCriteriaId":"F58A9CCD-3C23-4D1C-815E-C9D107F47B76"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:7.00-20140621:*:*:*:*:*:*:*","matchCriteriaId":"214CB7C5-6241-4589-AA91-014E334FFB41"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:7.00-20140729:*:*:*:*:*:*:*","matchCriteriaId":"46DC9731-1EA9-4354-959E-494905A45963"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:7.00-20141022:*:*:*:*:*:*:*","matchCriteriaId":"6F3DB916-F40E-4F80-9B28-0CB573585E1D"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:8.00-20140730:*:*:*:*:*:*:*","matchCriteriaId":"94994F4E-0F1D-46FC-A7B2-462838BA4DFD"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:panelview_plus_6_700-1500_firmware:8.00-20141023:*:*:*:*:*:*:*","matchCriteriaId":"8C8CD419-33AB-43C0-836F-8CC4AFD5F6FE"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:panelview_plus_6_700-1500:-:*:*:*:*:*:*:*","matchCriteriaId":"2B3064E9-5257-4D66-A127-E30944447752"}]}]}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-157-01","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-157-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}