{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-27T00:15:37.141","vulnerabilities":[{"cve":{"id":"CVE-2017-7689","sourceIdentifier":"cve@mitre.org","published":"2017-04-11T21:59:00.150","lastModified":"2026-06-17T01:24:59.460","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A Command Injection vulnerability in Schneider Electric homeLYnk Controller exists in all versions before 1.5.0."},{"lang":"es","value":"Existe una vulnerabilidad de Command Injection en Schneider Electric. El controlador HOMELYnk existe en todas las versiones anteriores a 1.5.0."}],"affected":[{"source":"cve@mitre.org","affectedData":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-77"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:homelynk_controller_lss100100_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.5.0","matchCriteriaId":"8706AB89-FEA6-43DC-8749-F2DA679FCF02"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:homelynk_controller_lss100100:-:*:*:*:*:*:*:*","matchCriteriaId":"69F69759-DDB2-4831-8E88-0D40BD9E7AE5"}]}]}],"references":[{"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-02","source":"cve@mitre.org","tags":["Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/97585","source":"cve@mitre.org","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-019-01A","source":"cve@mitre.org","tags":["Third Party Advisory","US Government Resource"]},{"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-02","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/97585","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-019-01A","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}