{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-08-02T13:39:28.835","vulnerabilities":[{"cve":{"id":"CVE-2017-2845","sourceIdentifier":"talos-cna@cisco.com","published":"2017-06-29T17:29:00.227","lastModified":"2026-06-17T01:16:58.930","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An exploitable command injection vulnerability exists in the web management interface used by the Foscam C1 Indoor HD Camera running application firmware 2.52.2.37. A specially crafted HTTP request can allow for a user to inject arbitrary shell characters during the SMTP configuration tests resulting in command execution"},{"lang":"es","value":"Existe una vulnerabilidad de inyección de comandos en la interfaz de gestión web empleada por Foscam C1 Indoor HD Camera que ejecuta el firmware de aplicación en su versión 2.52.2.37. Una petición HTTP especialmente manipulada puede permitir que un usuario inyecte caracteres shell arbitrarios durante las pruebas de configuración SMTP, lo que resulta en una ejecución de comandos."}],"affected":[{"source":"talos-cna@cisco.com","affectedData":[{"vendor":"Foscam","product":"Indoor IP Camera C1 Series","versions":[{"version":"n/a","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV30":[{"source":"talos-cna@cisco.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","baseScore":6.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-78"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:foscam:c1_indoor_hd_camera_firmware:2.52.2.37:*:*:*:*:*:*:*","matchCriteriaId":"0E42CC0A-E8B0-407C-A6B8-079CC10D2271"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:foscam:c1_indoor_hd_camera:-:*:*:*:*:*:*:*","matchCriteriaId":"24F43869-2168-407A-B546-06998CA5D572"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/99184","source":"talos-cna@cisco.com","tags":["Broken Link"]},{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2017-0347","source":"talos-cna@cisco.com","tags":["Technical Description","Third Party Advisory","VDB Entry"]},{"url":"http://www.securityfocus.com/bid/99184","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Broken Link"]},{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2017-0347","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Technical Description","Third Party Advisory","VDB Entry"]}]}}]}