{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-08-02T13:39:28.400","vulnerabilities":[{"cve":{"id":"CVE-2017-2844","sourceIdentifier":"talos-cna@cisco.com","published":"2017-06-29T17:29:00.180","lastModified":"2026-06-17T01:16:58.807","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"In the web management interface in Foscam C1 Indoor HD cameras with application firmware 2.52.2.37, a specially crafted HTTP request can allow for a user to inject arbitrary data in the \"msmtprc\" configuration file resulting in command execution. An attacker can simply send an HTTP request to the device to trigger this vulnerability."},{"lang":"es","value":"En la interfaz de gestión web en Foscam C1 Indoor HD Camera que ejecuta el firmware de aplicación en su versión 2.52.2.37, una petición HTTP especialmente manipulada puede permitir que un usuario inyecte datos arbitrarios en el archivo de configuración \"msmtprc\", lo que resulta en la ejecución de comandos. Un atacante puede simplemente enviar una petición HTTP al dispositivo para desencadenar esta vulnerabilidad."}],"affected":[{"source":"talos-cna@cisco.com","affectedData":[{"vendor":"Foscam","product":"Indoor IP Camera C1 Series","versions":[{"version":"n/a","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV30":[{"source":"talos-cna@cisco.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","baseScore":6.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-78"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:foscam:c1_indoor_hd_camera_firmware:2.52.2.37:*:*:*:*:*:*:*","matchCriteriaId":"0E42CC0A-E8B0-407C-A6B8-079CC10D2271"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:foscam:c1_indoor_hd_camera:-:*:*:*:*:*:*:*","matchCriteriaId":"24F43869-2168-407A-B546-06998CA5D572"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/99184","source":"talos-cna@cisco.com","tags":["Broken Link"]},{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2017-0346","source":"talos-cna@cisco.com","tags":["Technical Description","Third Party Advisory","VDB Entry"]},{"url":"http://www.securityfocus.com/bid/99184","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Broken Link"]},{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2017-0346","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Technical Description","Third Party Advisory","VDB Entry"]}]}}]}