{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-25T19:24:24.799","vulnerabilities":[{"cve":{"id":"CVE-2017-2843","sourceIdentifier":"talos-cna@cisco.com","published":"2017-06-27T15:29:00.237","lastModified":"2025-04-20T01:37:25.860","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"In the web management interface in Foscam C1 Indoor HD Camera running application firmware 2.52.2.37, a specially crafted HTTP request can allow for a user to inject arbitrary data in the \"msmtprc\" configuration file resulting in command execution. An attacker can simply send an HTTP request to the device to trigger this vulnerability."},{"lang":"es","value":"En la interfaz de gestión web de la cámara HD de interior Foscam C1 que ejecuta el firmware de la aplicación 2.52.2.37, una solicitud HTTP especialmente diseñada puede permitir a un usuario inyectar datos arbitrarios en el archivo de configuración \"msmtprc\", lo que da lugar a la ejecución de comandos. Un atacante puede simplemente enviar una solicitud HTTP al dispositivo para activar esta vulnerabilidad"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV30":[{"source":"talos-cna@cisco.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","baseScore":6.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-78"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:foscam:c1_indoor_hd_camera_firmware:2.52.2.37:*:*:*:*:*:*:*","matchCriteriaId":"0E42CC0A-E8B0-407C-A6B8-079CC10D2271"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:foscam:c1_indoor_hd_camera:-:*:*:*:*:*:*:*","matchCriteriaId":"24F43869-2168-407A-B546-06998CA5D572"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/99184","source":"talos-cna@cisco.com","tags":["Broken Link"]},{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2017-0345","source":"talos-cna@cisco.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"http://www.securityfocus.com/bid/99184","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Broken Link"]},{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2017-0345","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]}]}}]}