{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-09-29T14:19:56.147","vulnerabilities":[{"cve":{"id":"CVE-2017-2684","sourceIdentifier":"productcert@siemens.com","published":"2017-02-22T02:59:00.153","lastModified":"2026-06-17T01:16:39.757","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Siemens SIMATIC Logon prior to V1.5 SP3 Update 2 could allow an attacker with knowledge of a valid user name, and physical or network access to the affected system, to bypass the application-level authentication."},{"lang":"es","value":"Siemens SIMATIC Logon en versiones anteriores a V1.5 SP3 Update 2 podría permitir a un atacante con conocimiento de un nombre de usuario válido, y acceso físico o de red al sistema afectado, eludir la autenticación a nivel de aplicación."}],"affected":[{"source":"productcert@siemens.com","affectedData":[{"vendor":"n/a","product":"SIMATIC Logon All versions < V1.5 SP3 Update 2","versions":[{"version":"SIMATIC Logon All versions < V1.5 SP3 Update 2","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H","baseScore":9.0,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.2,"impactScore":6.0}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-592"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-noinfo"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_logon:*:sp3_update_1:*:*:*:*:*:*","versionEndIncluding":"1.5","matchCriteriaId":"0E791A5D-A304-4C65-84CA-859984342446"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/96208","source":"productcert@siemens.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-931064.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/96208","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-931064.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}