{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-09-29T22:04:46.087","vulnerabilities":[{"cve":{"id":"CVE-2017-18762","sourceIdentifier":"cve@mitre.org","published":"2020-04-22T16:15:11.373","lastModified":"2026-06-17T01:13:30.250","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6100 before 1.0.0.57, R6100 before 1.0.1.16, R6900P before 1.2.0.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, WNDR3700v4 before 1.0.2.88, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58."},{"lang":"es","value":"Determinados dispositivos NETGEAR están afectados por una inyección de comandos por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.68, D6000 versiones anteriores a 1.0.0.68, D6100 versiones anteriores a 1.0.0.57, R6100 versiones anteriores a 1.0.1.16, R6900P versiones anteriores a 1.2.0.22, R7000 versiones anteriores a 1.0.9.10, R7000P versiones anteriores a 1.2.0.22, R7100LG versiones anteriores a 1.0.0.40, WNDR3700v4 versiones anteriores a 1.0.2.88, WNDR4300v1 versiones anteriores a 1.0.2.90, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48 y WNR2000v5 versiones anteriores a 1.0.0.58."}],"affected":[{"source":"cve@mitre.org","affectedData":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV30":[{"source":"cve@mitre.org","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:A/AC:L/Au:N/C:P/I:P/A:P","baseScore":5.8,"accessVector":"ADJACENT_NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":6.5,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-74"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.0.68","matchCriteriaId":"D55132B3-B7CF-4BB9-B28B-406136D0C97B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*","matchCriteriaId":"31DE9D4E-3CDC-4552-A63F-DD5D95E23F63"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.0.68","matchCriteriaId":"2B5E3F3F-237F-4ADD-8853-CEBE78AAAC36"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*","matchCriteriaId":"6F6EA344-FF99-4F27-9860-3C5BE07345A7"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.0.57","matchCriteriaId":"2ECEA129-164C-4C80-A81E-9688F4AC3583"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*","matchCriteriaId":"7EFD1E86-F100-4E46-935D-903EB6FEFE9D"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.1.16","matchCriteriaId":"01A66936-4268-4990-8E83-24C74A75B9F6"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*","matchCriteriaId":"9F44A123-B256-428B-98C2-17570F2F32DC"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.2.0.22","matchCriteriaId":"A8D2A56D-4AAA-4E55-AE7A-E343EA9D6133"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*","matchCriteriaId":"C41908FF-AE64-4949-80E3-BEE061B2DA8A"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.9.10","matchCriteriaId":"DD7D570E-C5EF-4D3E-BCCF-926DBDB12016"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*","matchCriteriaId":"C9F86FF6-AB32-4E51-856A-DDE790C0A9A6"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.2.0.22","matchCriteriaId":"4E7FE05C-8ACF-4D53-A6D9-2C99673CE41A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*","matchCriteriaId":"DFE55F4D-E98B-46D3-B870-041141934CD1"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.0.40","matchCriteriaId":"EB388895-B579-43B7-A88E-4BD28D41F6E2"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*","matchCriteriaId":"366FA778-3C2A-42AF-9141-DAD7043B406C"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.2.88","matchCriteriaId":"3C2E8B48-CF6F-488A-A932-246B434CAF1B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*","matchCriteriaId":"257A5E68-8EDC-44F5-A85C-83A91C93CCE5"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.2.90","matchCriteriaId":"3D0CAC32-5F12-45E6-AC84-D9D5020A41E6"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*","matchCriteriaId":"D99E146D-B278-4CA6-8156-7D9923015779"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.0.48","matchCriteriaId":"8B1EBB8F-818F-4E04-BB25-A81C1C309CD0"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*","matchCriteriaId":"4428B145-B86D-4709-BBA9-64BDE7D35A25"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.0.48","matchCriteriaId":"9591B73B-93BF-4976-998B-0200C990EF6A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*","matchCriteriaId":"C31D6808-4103-4543-B7AB-84A79CD12006"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.0.58","matchCriteriaId":"9C819040-B30C-4393-9DD4-8E5744B13050"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*","matchCriteriaId":"317F25FF-B3A2-4C68-888F-D2627C564867"}]}]}],"references":[{"url":"https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451","source":"cve@mitre.org","tags":["Vendor Advisory"]},{"url":"https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}