{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-21T11:59:50.048","vulnerabilities":[{"cve":{"id":"CVE-2017-16749","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2018-03-15T23:29:00.360","lastModified":"2026-06-17T01:09:45.210","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A Use-after-Free issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files could exploit a use-after-free vulnerability."},{"lang":"es","value":"Se ha descubierto una vulnerabilidad de uso de memoria previamente liberada en Delta Industrial Automation Screen Editor de Delta Electronics en las versiones 2.00.23.00 y anteriores. Los archivos .dpb especialmente manipulados podrían explotar una vulnerabilidad de uso de memoria previamente liberada."}],"affected":[{"source":"ics-cert@hq.dhs.gov","affectedData":[{"vendor":"n/a","product":"Delta Electronics Delta Industrial Automation Screen Editor","versions":[{"version":"Delta Electronics Delta Industrial Automation Screen Editor","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-416"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-416"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:deltaww:delta_industrial_automation_screen_editor:*:*:*:*:*:*:*:*","versionEndIncluding":"2.00.23.00","matchCriteriaId":"1FE7B554-B7E3-4864-80E7-D49678FEBCC6"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/102426","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"http://www.securityfocus.com/bid/102426","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}