{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-09-24T00:25:00.061","vulnerabilities":[{"cve":{"id":"CVE-2017-14803","sourceIdentifier":"security@opentext.com","published":"2018-01-20T00:29:00.343","lastModified":"2026-06-17T01:06:47.403","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"In NetIQ Access Manager 4.3 and 4.4, a bug exists in Identity Server when accessing a basic SSO connector and downloading the BasicSSO connector plugins on IE11 where an attacker can execute arbitrary code on the system."},{"lang":"es","value":"En NetIQ Access Manager 4.3 y 4.4, existe un error en Identity Server al acceder a un conector SSO básico y descargar los plugins BasicSSO connector en IE11, donde un atacante puede ejecutar código arbitrario en el sistema."}],"affected":[{"source":"security@opentext.com","affectedData":[{"vendor":"Micro Focus","product":"NetIQ Access Manager","versions":[{"version":"4.3","status":"affected"},{"version":"4.4","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":10.0,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-noinfo"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:netiq:access_manager:4.3:*:*:*:*:*:*:*","matchCriteriaId":"51430A7A-F79D-445D-ABF8-A8B4ADE98FC3"},{"vulnerable":true,"criteria":"cpe:2.3:a:netiq:access_manager:4.4:*:*:*:*:*:*:*","matchCriteriaId":"36A890D3-618E-4060-9349-36BA7F7B4240"}]}]}],"references":[{"url":"https://www.novell.com/support/kb/doc.php?id=7022443","source":"security@opentext.com"},{"url":"https://www.novell.com/support/kb/doc.php?id=7022443","source":"af854a3a-2127-422b-91ae-364da2661108"}]}}]}