{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-08-01T08:59:24.091","vulnerabilities":[{"cve":{"id":"CVE-2017-14024","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2017-11-13T20:29:00.350","lastModified":"2026-06-17T01:05:27.647","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A Stack-based Buffer Overflow issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 Patch 1 and prior versions, and InTouch Machine Edition v8.0 SP2 Patch 1 and prior versions. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution with high privileges."},{"lang":"es","value":"Se descubrió un problema de desbordamiento de búfer basado en pila en Schneider Electric InduSoft Web Studio v8.0 SP2 Patch 1 o anterior y en InTouch Machine Edition v8.0 SP2 Patch 1 o anterior. La vulnerabilidad de desbordamiento de búfer basado en pila ha sido identificada. Podría permitir la ejecución remota de código con altos privilegios."}],"affected":[{"source":"ics-cert@hq.dhs.gov","affectedData":[{"vendor":"n/a","product":"Schneider Electric InduSoft Web Studio and InTouch Machine Edition","versions":[{"version":"Schneider Electric InduSoft Web Studio and InTouch Machine Edition","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":true,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-119"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:wonderware_indusoft_web_studio:*:sp2:*:*:*:*:*:*","versionEndIncluding":"8.0","matchCriteriaId":"909E4BF0-FD67-4F8B-B577-57E8E5F7A686"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:wonderware_intouch:*:sp2:*:*:machine:*:*:*","versionEndIncluding":"8.0","matchCriteriaId":"F51870FA-9C46-4C8B-83B0-3C32B0722581"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/101779","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-313-02","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"http://www.securityfocus.com/bid/101779","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-313-02","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}