{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-04T00:08:30.382","vulnerabilities":[{"cve":{"id":"CVE-2016-9158","sourceIdentifier":"productcert@siemens.com","published":"2016-12-17T03:59:00.187","lastModified":"2025-04-12T10:46:40.837","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en la familia de CPU SIMATIC S7-300 (todas las versiones), la familia de CPU SIMATIC S7-300 (incluidas las CPU ET200 relacionadas y las variantes SIPLUS) (todas las versiones), SIMATIC S7-400 PN / DP V6 y familias de CPU inferiores (incl. variantes SIPLUS) (todas las versiones), familia de CPU SIMATIC S7-400 PN / DP V7 (incl. variantes SIPLUS) (todas las versiones), SIMATIC S7-400 V6 y familia de CPU anterior (todas las versiones), SIMATIC S7-400 Familia de CPU V7 (todas las versiones). Los paquetes especialmente diseñados enviados al puerto 80 / tcp podrían hacer que los dispositivos afectados entren en modo defectuoso. Se requiere un reinicio en frío para recuperar el sistema."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:C","baseScore":7.8,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-20"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-20"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"76189399-9032-4695-A976-8415E26B0DB8"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-300_cpu_312:-:*:*:*:*:*:*:*","matchCriteriaId":"4FB328F8-3E03-440B-AB5C-ADA1D4F07F0E"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*","matchCriteriaId":"78399465-EED5-4EBD-A2E1-6FE0BD01EDB4"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*","matchCriteriaId":"E8FD8E6D-0527-4215-B6F0-5824011433FB"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_pn\\/dp:-:*:*:*:*:*:*:*","matchCriteriaId":"A773F92D-E5C0-4B51-8214-19BFE6BC7638"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-300_cpu_317-_2_dp:-:*:*:*:*:*:*:*","matchCriteriaId":"E3C5065F-C0B9-4427-A9D2-072AFF3FCA69"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-300_cpu_317-2_pn\\/dp:-:*:*:*:*:*:*:*","matchCriteriaId":"A340DA65-BA46-4F72-8951-93135F9F6602"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-300_cpu_319-3_pn\\/dp:-:*:*:*:*:*:*:*","matchCriteriaId":"7167E5B0-D278-4F63-B5CD-39DBDF336089"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_s7-400_cpu_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"F6EBD5F0-16A6-466B-80E5-B95DDBDE2FA3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-400_cpu_412-1:-:*:*:*:*:*:*:*","matchCriteriaId":"6498C679-46A3-4F87-9278-F64D2194E1F5"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2:-:*:*:*:*:*:*:*","matchCriteriaId":"85F8C306-45F5-429B-B932-0278A9B909B7"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*","matchCriteriaId":"F0E162F8-B37A-4FFA-A523-FA6227372D37"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-400_cpu_414-2:-:*:*:*:*:*:*:*","matchCriteriaId":"8CD1CA5C-F729-4311-9E78-156BB6DE31A7"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3:-:*:*:*:*:*:*:*","matchCriteriaId":"20E69856-A628-4B9D-9184-7FB9A924193E"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\/dp:-:*:*:*:*:*:*:*","matchCriteriaId":"A1EC8F19-313A-4C74-A68A-AAC320B123CE"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-400_cpu_416-2:-:*:*:*:*:*:*:*","matchCriteriaId":"195259DF-8ABE-47A9-9A13-6BDAA25AA898"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3:-:*:*:*:*:*:*:*","matchCriteriaId":"3412299F-5778-4290-A80C-29BC6F46F701"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\/dp:-:*:*:*:*:*:*:*","matchCriteriaId":"CC41E925-88AF-4D33-AC49-CE5FEAAF2105"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-2:-:*:*:*:*:*:*:*","matchCriteriaId":"61363AEF-CBDB-4405-A605-4997798D38D8"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-3_pn\\/dp:-:*:*:*:*:*:*:*","matchCriteriaId":"2CFC71AB-3ACF-4E7E-B83E-31E02DEBDA48"},{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_s7-400_cpu_417-4:-:*:*:*:*:*:*:*","matchCriteriaId":"711A91B2-EB16-418B-AA63-56DFD40075D7"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/94820","source":"productcert@siemens.com"},{"url":"http://www.securitytracker.com/id/1037434","source":"productcert@siemens.com"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf","source":"productcert@siemens.com"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05","source":"productcert@siemens.com"},{"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf","source":"productcert@siemens.com"},{"url":"http://www.securityfocus.com/bid/94820","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"http://www.securitytracker.com/id/1037434","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf","source":"af854a3a-2127-422b-91ae-364da2661108"}]}}]}