{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-07T04:20:15.330","vulnerabilities":[{"cve":{"id":"CVE-2016-5800","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2019-03-21T15:59:40.997","lastModified":"2024-11-21T02:55:02.070","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A malicious attacker can trigger a remote buffer overflow in the Communication Server in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0."},{"lang":"es","value":"Un atacante malicioso puede desencadenar un desbordamiento de búfer remoto en el servidor de comunicaciones en Fatek Automation PM Designer V3, en su versión 2.1.22; y Automation FV Designer, en su versión 1.2.8.0."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-121"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-119"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:fatek:automation_fv_designer:1.2.8.0:*:*:*:*:*:*:*","matchCriteriaId":"7932FA19-56F5-45CF-AD87-89F1154BD26C"},{"vulnerable":true,"criteria":"cpe:2.3:a:fatek:automation_pm_designer_v3:2.1.2.2:*:*:*:*:*:*:*","matchCriteriaId":"377EEDDC-3DBC-4987-8A04-2D9820D20890"}]}]}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-287-06","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-16-287-06","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}