{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-15T17:34:58.175257900Z","vulnerabilities":[{"cve":{"id":"CVE-2016-1036","sourceIdentifier":"psirt@adobe.com","published":"2016-04-22T18:59:01.097","lastModified":"2025-04-12T10:46:40.837","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"Cross-site scripting (XSS) vulnerability in Adobe Analytics AppMeasurement for Flash Library before 4.0.1, when debugTracking is enabled, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."},{"lang":"es","value":"Vulnerabilidad de XSS en Adobe Analytics AppMeasurement para Flash Library en versiones anteriores a 4.0.1, cuando debugTracking está activado, permite a atacantes remotos inyectar secuencias de comandos web o HTML arbitrarios a través de vectores no especificados."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:adobe:analytics_appmeasurement_for_flash_library:*:*:*:*:*:*:*:*","versionEndIncluding":"4.0","matchCriteriaId":"8DB672C2-4D43-4CA3-850A-E9C6BB889263"}]}]}],"references":[{"url":"http://www.securitytracker.com/id/1035671","source":"psirt@adobe.com"},{"url":"https://helpx.adobe.com/security/products/analytics/apsb16-13.html","source":"psirt@adobe.com","tags":["Vendor Advisory"]},{"url":"http://www.securitytracker.com/id/1035671","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://helpx.adobe.com/security/products/analytics/apsb16-13.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}