{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-25T11:54:40.683","vulnerabilities":[{"cve":{"id":"CVE-2015-1007","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2019-03-25T19:29:00.243","lastModified":"2024-11-21T02:24:28.883","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A specially crafted configuration file could be used to cause a stack-based buffer overflow condition in the OPCTest.exe, which may allow remote code execution on Opto 22 PAC Project Professional versions prior to R9.4008, PAC Project Basic versions prior to R9.4008, PAC Display Basic versions prior to R9.4g, PAC Display Professional versions prior to R9.4g, OptoOPCServer version R9.4c and prior that were installed by PAC Project installer, versions prior to R9.4008, and OptoDataLink version R9.4d and prior that were installed by PAC Project installer, versions prior to R9.4008. Opto 22 suggests upgrading to the new product version as soon as possible."},{"lang":"es","value":"Un archivo de configuración especialmente manipulado podría ser utilizado para provocar un desbordamiento de búfer basado en pila en el OPCTest.exe, lo cual podría permitir la ejecución remota de código en Opto 22 PAC Project Professional, en versiones anteriores a la R9.4008, PAC Project Basic en versiones anteriores a la R9.4008, PAC Display Basic en versiones anteriores a la R9.4g, PAC Display Professional en versiones anteriores a la R9.4g y OptoOPCServer en su versión R9.4c y anteriores, que fueron instaladas por PAC Project installer, en versiones anteriores a la R9.4008, y en OptoDataLink en su versión R9.4d y anteriores, que fueron instaladas por PAC Project installer, en versiones anteriores a la R9.4008. Opto 22 recomienda que se actualice el producto a la versión más reciente cuanto antes."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:C/I:C/A:C","baseScore":9.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":8.6,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-121"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-119"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:opto22:optodatalink:*:*:*:*:*:*:*:*","versionEndIncluding":"r9.4d","matchCriteriaId":"3A839A0F-A9C2-4F2A-87F0-19BEB6E3F561"},{"vulnerable":true,"criteria":"cpe:2.3:a:opto22:optoopcserver:*:*:*:*:*:*:*:*","versionEndIncluding":"r9.4c","matchCriteriaId":"BE3E7161-4D6B-419D-BF56-B8A9C0796D83"},{"vulnerable":true,"criteria":"cpe:2.3:a:opto22:pac_display:*:*:*:*:basic:*:*:*","versionEndExcluding":"r9.4g","matchCriteriaId":"393DE6C4-A6AE-4AF9-8555-F8A4DF2028CC"},{"vulnerable":true,"criteria":"cpe:2.3:a:opto22:pac_display:*:*:*:*:professional:*:*:*","versionEndExcluding":"r9.4g","matchCriteriaId":"9F38A3B6-F010-4A6B-ABD0-AA3E77C31CD9"},{"vulnerable":true,"criteria":"cpe:2.3:a:opto22:pac_project:*:*:*:*:basic:*:*:*","versionEndExcluding":"r9.4008","matchCriteriaId":"042A1505-4EF3-4CFA-9187-EFB4CCB6A0FA"},{"vulnerable":true,"criteria":"cpe:2.3:a:opto22:pac_project:*:*:*:*:professional:*:*:*","versionEndExcluding":"r9.4008","matchCriteriaId":"A0AC2D7E-D720-4299-BE1D-7EE45709A226"}]}]}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-120-01","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-120-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}