{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-27T01:40:20.929","vulnerabilities":[{"cve":{"id":"CVE-2014-9188","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2014-12-27T15:59:04.887","lastModified":"2025-07-24T23:15:24.770","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514.  NOTE: this may be clarified later based on details provided by researchers."},{"lang":"es","value":"Desbordamiento de buffer en el control ActiveX en MDraw30.ocx en Schneider Electric ProClima anterior a 6.1.7 permite a atacantes remotos ejecutar código arbitrario a través de vectores sin especificar, una vulnerabilidad diferente a CVE-2014-8513 y CVE-2014-8514. NOTA: esto se puede aclarar después en base a los detalles proporcionados por los investigadores."}],"metrics":{"cvssMetricV2":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":10.0,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:P/A:P","baseScore":9.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":8.5,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-77"}]},{"source":"nvd@nist.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-119"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider_electric:proclima:*:*:*:*:*:*:*:*","versionEndIncluding":"6.0.1","matchCriteriaId":"47B0392E-5225-40CD-B1CB-8761B69A743E"}]}]}],"references":[{"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01","source":"ics-cert@hq.dhs.gov","tags":["Patch","Vendor Advisory"]},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-350-01","source":"ics-cert@hq.dhs.gov"},{"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Third Party Advisory","US Government Resource"]}]}}]}