{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-15T21:30:13.042","vulnerabilities":[{"cve":{"id":"CVE-2014-2355","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2015-01-17T02:59:00.067","lastModified":"2025-10-03T17:15:45.633","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"The (1) CimView and (2) CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen (aka .CIM) file."},{"lang":"es","value":"Los componentes (1) CimView y (2) CimEdit en GE Proficy HMI/SCADA-CIMPLICITY 8.2 y anteriores permiten a atacantes remotos ganar privilegios a través de un fichero de pantalla CIMPLICITY manipulado (también conocido como .CIM)."}],"metrics":{"cvssMetricV2":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:M/Au:S/C:C/I:C/A:C","baseScore":6.6,"accessVector":"LOCAL","accessComplexity":"MEDIUM","authentication":"SINGLE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"MEDIUM","exploitabilityScore":2.7,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:M/Au:N/C:C/I:C/A:C","baseScore":6.9,"accessVector":"LOCAL","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"MEDIUM","exploitabilityScore":3.4,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-119"}]},{"source":"nvd@nist.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-119"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:*:*:*:*:*:*:*:*","versionEndIncluding":"8.2","matchCriteriaId":"05C547A7-08D0-475E-BD24-57CC3DF2F89E"}]}]}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-289-02","source":"ics-cert@hq.dhs.gov"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-14-289-02","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}