{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-15T19:30:11.418","vulnerabilities":[{"cve":{"id":"CVE-2014-2343","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2014-05-30T23:55:02.783","lastModified":"2026-05-06T22:30:45.220","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows physically proximate attackers to cause a denial of service (excessive data processing) via a crafted DNP request over a serial line."},{"lang":"es","value":"Triangle MicroWorks SCADA Data Gateway anterior a 3.00.0635 permite a atacantes físicamente próximos causar una denegación de servicio (procesamiento de datos excesivo) a través de una solicitud DNP manipulada sobre una línea de serie."}],"metrics":{"cvssMetricV2":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:H/Au:N/C:N/I:N/A:P","baseScore":1.2,"accessVector":"LOCAL","accessComplexity":"HIGH","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"LOW","exploitabilityScore":1.9,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:N/I:N/A:P","baseScore":2.1,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"LOW","exploitabilityScore":3.9,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-400"}]},{"source":"nvd@nist.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-20"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*","versionEndIncluding":"3.00.0633","matchCriteriaId":"A505671F-8C57-47A2-89D4-DC6186F5D7DA"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50:*:*:*:*:*:*:*","matchCriteriaId":"D2626C47-B68A-4A21-B5A2-9D64A28A7120"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50.0309:*:*:*:*:*:*:*","matchCriteriaId":"69D2B52D-B324-4115-A3BB-51E3BF97758B"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.51:*:*:*:*:*:*:*","matchCriteriaId":"9406C4EC-5758-458D-8354-6736CA78A660"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.53:*:*:*:*:*:*:*","matchCriteriaId":"EB915370-216E-40DC-AEF5-634230394E00"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0515:*:*:*:*:*:*:*","matchCriteriaId":"22E5498C-D5F0-43F7-A536-AB65B4DEB49F"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0516:*:*:*:*:*:*:*","matchCriteriaId":"2099DFC5-F241-4C47-9A17-FE40101A4570"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0517:*:*:*:*:*:*:*","matchCriteriaId":"F1E898A9-7F0E-453C-8509-75E7E1290382"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0518:*:*:*:*:*:*:*","matchCriteriaId":"E513983A-C6A2-4E07-874B-880F7A013D53"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0528:*:*:*:*:*:*:*","matchCriteriaId":"D6861F70-5798-4B41-BE94-BECCF16752BB"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0529:*:*:*:*:*:*:*","matchCriteriaId":"1B5722CA-130A-46B3-9A30-9661069890AF"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0536:*:*:*:*:*:*:*","matchCriteriaId":"F5E625A4-30E4-4D5B-81B2-B0B0569948DB"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0540:*:*:*:*:*:*:*","matchCriteriaId":"5A6D03B5-2E8C-49E9-8A18-F367F72A4D50"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0544:*:*:*:*:*:*:*","matchCriteriaId":"AF59F8E0-C4BA-4658-9B91-BACD59B9C482"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0545:*:*:*:*:*:*:*","matchCriteriaId":"BD36BB8A-C840-494B-835C-98EB0075CA62"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0552:*:*:*:*:*:*:*","matchCriteriaId":"8FDB5301-887B-4950-A918-113B75D2BDE5"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0553:*:*:*:*:*:*:*","matchCriteriaId":"76BF9332-5F3E-4230-A742-2019B2DCEB22"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0558:*:*:*:*:*:*:*","matchCriteriaId":"1610F5AE-3BB1-4BDB-8C88-A2B83DBE39C1"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0561:*:*:*:*:*:*:*","matchCriteriaId":"1E2A4B7A-D8DA-4A1E-8506-A2D377E7568D"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0562:*:*:*:*:*:*:*","matchCriteriaId":"90EA0A71-B4C7-4F54-A439-4B0FA9637410"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0564:*:*:*:*:*:*:*","matchCriteriaId":"71B02213-096E-4CA2-8528-64E83EA06D27"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0565:*:*:*:*:*:*:*","matchCriteriaId":"8EA1B917-A27E-4043-BD74-534B13916F3B"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0566:*:*:*:*:*:*:*","matchCriteriaId":"378C61EE-9420-42D3-9DA2-71F2D459ACE9"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0567:*:*:*:*:*:*:*","matchCriteriaId":"CA21BE3B-6C2E-4479-A9A0-E3966741B832"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0569:*:*:*:*:*:*:*","matchCriteriaId":"49C97936-8AF3-41D8-8D6B-F6C9C5F4B002"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0570:*:*:*:*:*:*:*","matchCriteriaId":"D3175298-E0A4-4571-BDCC-FDA81675BC67"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0571:*:*:*:*:*:*:*","matchCriteriaId":"18BF8DF0-93D1-4ACA-BA78-B6DE0080AD52"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0572:*:*:*:*:*:*:*","matchCriteriaId":"E1D5F9B2-38C5-45AC-9A33-80E61BAF0E17"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0573:*:*:*:*:*:*:*","matchCriteriaId":"00666362-AD62-4942-96E8-C08BF087E34F"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0574:*:*:*:*:*:*:*","matchCriteriaId":"5BC82C89-7D15-452D-8610-23F3952487E9"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0575:*:*:*:*:*:*:*","matchCriteriaId":"3D15DD91-4F01-4B95-8F9A-C4848800BDBB"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0576:*:*:*:*:*:*:*","matchCriteriaId":"9DF57506-CC34-473C-8165-CB26194E80BB"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0577:*:*:*:*:*:*:*","matchCriteriaId":"CC480C77-1950-4C3A-B77E-D2C2AC59FE20"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0578:*:*:*:*:*:*:*","matchCriteriaId":"2044B8C6-D0C6-4A1E-9798-19912FFAE097"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0579:*:*:*:*:*:*:*","matchCriteriaId":"40D4B1C5-CE06-4082-9534-513BB99D7D7B"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0580:*:*:*:*:*:*:*","matchCriteriaId":"15E62697-E6BD-4796-9470-F6E125CD3F4C"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0581:*:*:*:*:*:*:*","matchCriteriaId":"299D658E-143A-4556-A6FF-37EDA07828CF"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0582:*:*:*:*:*:*:*","matchCriteriaId":"7619010A-954E-4F5D-8DDB-0ED652E2A306"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0583:*:*:*:*:*:*:*","matchCriteriaId":"C042A0EB-AB96-4FD2-A19E-4E9101C2C63C"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0584:*:*:*:*:*:*:*","matchCriteriaId":"B8B7B997-4D7F-4A34-822A-3AF52A4FA715"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0586:*:*:*:*:*:*:*","matchCriteriaId":"3E073D1B-4FBF-4DE2-AA5A-1EE8774D20FD"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0587:*:*:*:*:*:*:*","matchCriteriaId":"2285B98B-3E80-4C5B-9D7D-DA7C250FBAD0"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0588:*:*:*:*:*:*:*","matchCriteriaId":"0EC58901-067E-485B-9723-9F344F306C39"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0589:*:*:*:*:*:*:*","matchCriteriaId":"E4583789-CC14-48BB-83B5-AF1B6896B10B"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0590:*:*:*:*:*:*:*","matchCriteriaId":"7CEC3409-0CED-41A8-8718-B0EFCA85DA49"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0591:*:*:*:*:*:*:*","matchCriteriaId":"B4AEB67C-7DAF-44D2-BB32-FD9E86D8EA0A"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0592:*:*:*:*:*:*:*","matchCriteriaId":"383DA8F4-1DDD-43A9-8A53-721F5F449CA2"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0594:*:*:*:*:*:*:*","matchCriteriaId":"1AD95D30-4502-44EB-9C0C-D9A45CD24E5C"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0595:*:*:*:*:*:*:*","matchCriteriaId":"B9F60297-9FA4-47F6-98AF-B9662568D76F"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0596:*:*:*:*:*:*:*","matchCriteriaId":"4E593FD2-7158-40D0-9F44-01C06BF96F06"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0597:*:*:*:*:*:*:*","matchCriteriaId":"0D8A435F-8C6D-4584-8DB9-4A0C515F6D3B"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0598:*:*:*:*:*:*:*","matchCriteriaId":"5F210B77-F989-4931-AFBF-CEC2A175FC27"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0599:*:*:*:*:*:*:*","matchCriteriaId":"36BBE6AE-BEE1-441B-A5A4-30BD7FCFBF3B"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00:*:*:*:*:*:*:*","matchCriteriaId":"F74C4546-500F-405C-B585-6F6C07065808"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0612:*:*:*:*:*:*:*","matchCriteriaId":"948521F4-CA30-4269-8A98-96F9AD004150"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0615:*:*:*:*:*:*:*","matchCriteriaId":"9D9853CB-38CC-419D-A9F8-EDDA2F6CE4F8"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0616:*:*:*:*:*:*:*","matchCriteriaId":"7C679459-44C7-454C-9894-87ABE1F710F2"},{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0630:*:*:*:*:*:*:*","matchCriteriaId":"CD169173-9189-42BE-A741-955889E44FC9"}]}]}],"references":[{"url":"http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new","source":"ics-cert@hq.dhs.gov"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-149-01","source":"ics-cert@hq.dhs.gov"},{"url":"http://ics-cert.us-cert.gov/advisories/ICSA-14-149-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["US Government Resource"]},{"url":"http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new","source":"af854a3a-2127-422b-91ae-364da2661108"}]}}]}