{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-23T02:35:56.860","vulnerabilities":[{"cve":{"id":"CVE-2010-4100","sourceIdentifier":"hp-security-alert@hp.com","published":"2010-11-02T02:26:30.583","lastModified":"2025-04-11T00:51:21.963","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"Unspecified vulnerability in HP Insight Control Performance Management before 6.1 update 2 allows remote attackers to read arbitrary files via unknown vectors."},{"lang":"es","value":"Vulnerabilidad sin especificar en HP Insight Control Performance Management en versiones anteriores a la 6.1 update 2. Permite a atacantes remotos leer ficheros arbitrarios a través de vectores de ataque desconocidos."}],"metrics":{"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-noinfo"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:hp:insight_control_performance_management:*:*:*:*:*:*:*:*","versionEndIncluding":"6.1","matchCriteriaId":"FC50A1B4-F87F-4B81-8F46-72DC9F6842BA"},{"vulnerable":true,"criteria":"cpe:2.3:a:hp:insight_control_performance_management:5.0:*:*:*:*:*:*:*","matchCriteriaId":"6DED9C52-46C8-405F-A9A9-602A37153062"},{"vulnerable":true,"criteria":"cpe:2.3:a:hp:insight_control_performance_management:5.2:*:*:*:*:*:*:*","matchCriteriaId":"E9D46E59-63F8-4FF0-882E-F0FB963121D6"},{"vulnerable":true,"criteria":"cpe:2.3:a:hp:insight_control_performance_management:5.2.2:*:*:*:*:*:*:*","matchCriteriaId":"98E0B488-6030-4970-9D2A-589028A72FAE"},{"vulnerable":true,"criteria":"cpe:2.3:a:hp:insight_control_performance_management:6.0:*:*:*:*:*:*:*","matchCriteriaId":"B0E2234A-8F58-4549-B6F0-9CA7A8E0ACFE"}]}]}],"references":[{"url":"http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c02574359","source":"hp-security-alert@hp.com","tags":["Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/44583","source":"hp-security-alert@hp.com"},{"url":"http://www.securitytracker.com/id?1024675","source":"hp-security-alert@hp.com"},{"url":"http://www.vupen.com/english/advisories/2010/2833","source":"hp-security-alert@hp.com","tags":["Vendor Advisory"]},{"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/62883","source":"hp-security-alert@hp.com"},{"url":"http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c02574359","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/44583","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"http://www.securitytracker.com/id?1024675","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"http://www.vupen.com/english/advisories/2010/2833","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/62883","source":"af854a3a-2127-422b-91ae-364da2661108"}]}}]}